All Products
-
Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
Fluke 376 FC True-RMS Clamp Meter with iFlex 2500 A Range 0.1 A Resolution

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
Range | 2500 A | Resolution | 0.1 A |
---|---|---|---|
Accuracy | 3% ±5 Digits (5 – 500 Hz) | ||
Highlight | 2500 A Range Clamp Meter,0.1 A Resolution Clamp Meter |
Product Description
General Specifications | ||||||
AC Current via Jaw | ||||||
Range | 999.9 A | |||||
Resolution | 0.1 A | |||||
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |||||
2.5% ±5 digits (100-500 Hz) | ||||||
Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |||||
2.5 @ 600 A | ||||||
Add 2% for C.F. >2 | ||||||
AC Current via Flexible Current Probe | ||||||
Range | 2500 A | |||||
Resolution | 0.1 A (≤ 600 A) | |||||
1 A (≤ 2500 A) | ||||||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||||
Crest Factor (50/60Hz) | 3.0 at 1100 A | |||||
2.5 at 1400 A | ||||||
1.42 at 2500 A | ||||||
Add 2% for C.F. > 2 | ||||||
i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | ||||
A | ||||||
Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) | |||
Error | ±0.5 % | ±0.5 % | ±0.5 % | |||
B | ||||||
Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) | |||
Error | ±1.0 % | ±1.0 % | ±1.0 % | |||
C | ||||||
Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) | |||
Error | ±2.0 % | ±2.0 % | ±2.0 % | |||
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||||
DC Current | ||||||
Range | 999.9 A | |||||
Resolution | 0.1 A | |||||
Accuracy | 2% ±5 digits | |||||
AC Voltage | ||||||
Range | 1000 V | |||||
Resolution | 0.1 V (≤600.0 V) | |||||
1 V (≤1000 V) | ||||||
Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |||||
DC Voltage | ||||||
Range | 1000 V | |||||
Resolution | 0.1 V (≤600.0 V) | |||||
1 V (≤1000 V) | ||||||
Accuracy | 1% ±5 digits | |||||
mV dc | ||||||
Range | 500.0 mV | |||||
Resolution | 0.1 mV | |||||
Accuracy | 1% ±5 digits | |||||
Frequency via Jaw | ||||||
Range | 5.0 Hz to 500.0 Hz | |||||
Resolution | 0.1 Hz | |||||
Accuracy | 0.5% ±5 digits | |||||
Trigger level | 5 Hz to 10 Hz, ≥10 A | |||||
10 Hz to 100 Hz, ≥5 A | ||||||
100 Hz to 500 Hz, ≥10 A | ||||||
Frequency via Flexible Current Probe | ||||||
Range | 5.0 Hz to 500.0 Hz | |||||
Resolution | 0.1 Hz | |||||
Accuracy | 0.5% ±5 digits | |||||
Trigger level | 5 Hz to 20 Hz, ≥25 A | |||||
20 Hz to 100 Hz, ≥20 A | ||||||
100 Hz to 500 Hz, ≥25 A |
Recommended Products