XC3-32R-E Programmable Logic Controller PLC CPU Relay
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Warranty | 1 Year | Type | PLC |
|---|---|---|---|
| Input Signal Voltage | 24VDC +/- 10% | Real Time Clock | Yes |
| Condition | New And Original | Quality | High-quality |
| Highlight | Programmable PLC CPU Relay,PLC Logic Controller XC3-32R-E,PLC Programming Logic Controller Relay |
||
| Scan Time | 0 - 99 mS | |
|---|---|---|
| Power supply | 90- 260 VAC | |
| Ambient Humidity | 5%~95% | |
| Dispose Speed | 0.5us | |
| Output Format | Relay | |
| Data Register(D) | 8512 characters |
![]()
Features:
18 DI/14 DO, AC220 or DC24V power supply;
Can be expanded with expansion module, BD board.
Support RTC, power-off retentive;
Support basic logic control and data operation;
Support high speed count, pulse output, exterior interruption, C language function block, free switch for I/O points, free protocol communication and MODBUS communication.
Specifications:
General
| Item | Specification |
| Insulation Voltage | Above DC 500V 2Mohm |
| Noise Resistance | 1000V 1uS pulse for 1 minute |
| Environment Temperature | 0centigrade degree~6centigrade degree |
| Ambient Humidity | 5%~95% |
| COM 1 | RS-232, be connected to host machine or HMI for programming or debugging |
| COM 2 | RS-485/RS-232, network or connect to intelligent instrument, inverter, etc. |
| COM 3 | BD extensional communication port RS-485/RS232 |
| Installation | M3 screw fixed or DIN46277 (35mm width) guide rail installation |
| Grounding | The third type grounding (Never perform common grounding with strong power system) |
Performance:
| Item | Specification | |
| Program Operation Mode | Circulation scanning mode, timing scanning mode | |
| Program Mode | Instructions and ladder chart | |
| Dispose Speed | 0.5us | |
| Power Failure Holding | FlashROM | |
| User Program’s Capacity | 8000 steps | |
| I/O Points | 18 input points, 14 output points | |
| Output Format | Relay | |
| Power Supply | AC220V/DC24V | |
| Interior Coil’s Points (M) | 8512 points | |
| Timer(T) | Points | 620 points |
| Specification |
100mS timer: set time 0.1~3276.7 seconds 10mS timer: set time 0.01~327.67 seconds 1mS timer: set time 0.001~32.767 seconds |
|
| Counter(C) | Points | 635 Points |
| Specification |
16 bits counter: Set value K0~32767 32 bits counter: Set value K0~2147483647 |
|
| Data Register(D) | 8512 characters | |
| FlashROM Register(FD) | 2048 characters | |
| High-speed Count Format | High speed counter, pulse output, exterior interruption | |
| Timing Scanning Interval Setting | 1~99mS | |
| Password Protection | 6 characters ASCII | |
| Self-diagnose Function | Power on self-diagnose, monitor timer, grammar check | |
Product appearance and size chart
Dimension :unit (mm) chart
![]()
![]()
![]()
![]()
![]()