XC3-32R-E Programmable Logic Controller PLC CPU Relay

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWarranty | 1 Year | Type | PLC |
---|---|---|---|
Input Signal Voltage | 24VDC +/- 10% | Real Time Clock | Yes |
Condition | New And Original | Quality | High-quality |
Highlight | Programmable PLC CPU Relay,PLC Logic Controller XC3-32R-E,PLC Programming Logic Controller Relay |
Scan Time | 0 - 99 mS | |
---|---|---|
Power supply | 90- 260 VAC | |
Ambient Humidity | 5%~95% | |
Dispose Speed | 0.5us | |
Output Format | Relay | |
Data Register(D) | 8512 characters |
Features:
18 DI/14 DO, AC220 or DC24V power supply;
Can be expanded with expansion module, BD board.
Support RTC, power-off retentive;
Support basic logic control and data operation;
Support high speed count, pulse output, exterior interruption, C language function block, free switch for I/O points, free protocol communication and MODBUS communication.
Specifications:
General
Item | Specification |
Insulation Voltage | Above DC 500V 2Mohm |
Noise Resistance | 1000V 1uS pulse for 1 minute |
Environment Temperature | 0centigrade degree~6centigrade degree |
Ambient Humidity | 5%~95% |
COM 1 | RS-232, be connected to host machine or HMI for programming or debugging |
COM 2 | RS-485/RS-232, network or connect to intelligent instrument, inverter, etc. |
COM 3 | BD extensional communication port RS-485/RS232 |
Installation | M3 screw fixed or DIN46277 (35mm width) guide rail installation |
Grounding | The third type grounding (Never perform common grounding with strong power system) |
Performance:
Item | Specification | |
Program Operation Mode | Circulation scanning mode, timing scanning mode | |
Program Mode | Instructions and ladder chart | |
Dispose Speed | 0.5us | |
Power Failure Holding | FlashROM | |
User Program’s Capacity | 8000 steps | |
I/O Points | 18 input points, 14 output points | |
Output Format | Relay | |
Power Supply | AC220V/DC24V | |
Interior Coil’s Points (M) | 8512 points | |
Timer(T) | Points | 620 points |
Specification |
100mS timer: set time 0.1~3276.7 seconds 10mS timer: set time 0.01~327.67 seconds 1mS timer: set time 0.001~32.767 seconds |
|
Counter(C) | Points | 635 Points |
Specification |
16 bits counter: Set value K0~32767 32 bits counter: Set value K0~2147483647 |
|
Data Register(D) | 8512 characters | |
FlashROM Register(FD) | 2048 characters | |
High-speed Count Format | High speed counter, pulse output, exterior interruption | |
Timing Scanning Interval Setting | 1~99mS | |
Password Protection | 6 characters ASCII | |
Self-diagnose Function | Power on self-diagnose, monitor timer, grammar check |
Product appearance and size chart
Dimension :unit (mm) chart