-
Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
XL5 Programmable Logic Controller DC 500V 2MΩ Plc Programming Device

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xAmbient Temperature | 0℃~55℃ | Product Name | Programmable Logic Controller |
---|---|---|---|
Insulation Voltage | Above DC 500V 2MΩ | Ambient Humidity | 5%~95% |
Installation | M3 Screws Or On The Guide Rail | Anti Noise | Noise Voltage 1000Vp-p 1us Pulse 1 Minute |
Highlight | XL5 Programmable Logic Controller,Programmable Logic Controller DC 500V,500V 2MΩ Plc Programming Device |
XL5 series PLC
Product description
Slim PLC, compact and practical, saving installation space
Support 2 ~ 4 channels of high-speed pulse output and 3 ~ 4 channels of AB phase high-speed counting
8 / 16 / 32 points input and 8 / 16 / 32 points output; Transistor output, DC24V power supply
Up to 16 expansion modules and 1 ED module can be expanded externally
Support USB port high-speed download
It has higher processing speed, about 12 times that of XC series
With clock and data power down holding function
Support basic logic control and data operation
Support X-NET fieldbus, PID, external interrupt, C function block, MODBUS communication and other functions
Model list
Note: PNP PLC can be customized.
Function configuration table × Not support √ support
|
Note: all models are equipped with clock function as standard.
General Specifications
Item | Specification |
Insulation voltage | Above DC 500V 2MΩ |
Anti noise | Noise voltage 1000Vp-p 1us pulse 1 minute |
Air | No corrosive and combustible gas |
Ambient temperature | 0℃~55℃ |
Ambient humidity | 5%~95% (no condensation) |
USB port | USB port, XNET protocol, for upload/download porgram and monitoring |
COM1 | RS232, connect upper computer, HMI to programming and debug |
COM2 | RS485, connect intelligent instruments, frequency converters, etc |
COM3 | For left expansion ED module |
Installation | It can be fixed with M3 screws or directly installed on the guide rail |
Ground (FG) | The third kind of grounding (not common grounding with strong current system) |
Functional Specifications
Item | Specification | |||||
Program execution mode | Loop scan mode | |||||
Programming mode | Command and ladder chart | |||||
Processing speed | 0.05us | |||||
Power-off retentive | FlashROM and 3V lithium battery | |||||
User program capacity ※1 | 512kB | |||||
I/O points ※2 |
Total points | 16 points | 32 points | 64 points | ||
Input points |
8 points X0~X7 |
16 points X0~X17 | 32 points X0~X37 | |||
Output points |
8 points Y0~Y7 |
16 points Y0~Y17 | 32 points Y0~Y37 | |||
Internal coils (X)※3 | 1280 points: X0~X77, X10000~X11777, X20000~X20177, X30000~X30077 | |||||
Internal coils (Y) ※4 | 1280 points: Y0~Y77, Y10000~Y11777, Y20000~Y20177, Y30000~Y30077 | |||||
Internal coils (M, HM) |
87000 points | M0~M69999【HM0~HM11999】※5 | ||||
Special use ※6 SM0~SM4999 | ||||||
Flow (S) | 9000 points | S0~S7999【HS0~HS999】 | ||||
Timer (T) | Points | 7000 points | T0~T4999【HT0~HT1999】 | |||
Spec |
100ms timer: 0.1~3276.7s 10ms timer: 0.01~327.67s 1ms timer: 0.001~32.767s |
|||||
Counter (C) | Points | 7000 points | C0~C4999【HC0~HC1999】 | |||
Spec |
16-bit counter: K0~32,767 32-bit counter: -2147483648~+2147483647 |
|||||
Data register (D) | 100000 words | D0~D69999【HD0~HD24999】※5 | ||||
Special use ※6 SD0~SD4999 | ||||||
FlashROM register (FD) |
14192 words | FD0~FD8191 | ||||
Special use ※6 SFD0~SFD5999 | ||||||
High speed processing ability | High speed counter, pulse output, external interruption | |||||
Password protection | 6-bit ASCII | |||||
Self-diagnose function | Power on self-check, monitor timer, grammar check |
Notes:
※ 1: User program capacity refers to the maximum program capacity during secret download.
※ 2: I / O points refer to the number of terminals that users can access and output signals from the outside.
※ 3: X refers to the internal input relay, and X exceeding I points can be used as intermediate relay.
※ 4: y refers to the internal output relay. Y exceeding O points can be used as an intermediate relay.
※ 5: [ ] flag, which is the default power-off holding area and cannot be changed.
※ 6: Special use refers to the special purpose register occupied by the system, which can not be used for other purposes.
※ 7: The numbers of input coils and output relays / transistors are octal numbers, and the numbers of other memories are decimal numbers.
※ 8: I / O without real connection with peripheral equipment can be used as fast internal relay.