Electronics Marine Radar Magnetron For Maritime Navigation Communication MG5436 E2V 25KW
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xBrand Name | Magnetron | Type | Marine Radar |
---|---|---|---|
Typical Peak Power | 25 KW | Heater Voltage | 6.3 V |
Highlight | Electronics Marine Radar Magnetron,Navigation Communication Marine Radar Magnetron,Maritime Magnetron Ship Radar |
Warranty | 1 year | |
---|---|---|
Operating Frequency | 9410 MHz + 30 | |
Heater current | 6.3 V: 0.5 A | |
Anode temperature | 120℃ |
EEV MG5436 25kW X-band Marine Radar Magnetron
- Operating Frequency: 9410 MHz + 30
- Typical peak power: 25 kW
- Heater voltage: 6,3 V
- Heater current at 6.3 V: 0.5 A
- The minimum clearance of 25 mm must be maintained between the magnetron and any magnetic material.
Brand Name | E2V |
Part | MAGNETRON |
New Original | YES |
POWER | 25KW |
FREQUENCY | 9410 + 30 MHz |
Weight | 2Kg |
HEALTH AND SAFETY HAZARDS
E2V Technologies magnetrons are safe to handle and operate, provided that the relevant precautions stated herein are observed. E2V Technologies does not accept responsibility for damage or injury resulting from the use of electronic devices it produces. Equipment manufacturers and users must ensure that adequate precautions are taken. Appropriate warning labels and notices must be provided on equipments incorporating E2V Technologies devices and in operating manuals.
High Voltage
Equipment must be designed so that personnel cannot come into contact with high voltage circuits. All high voltage circuits and terminals must be enclosed and fail-safe interlock switches must be fitted to disconnect the primary power supply and discharge all high voltage capacitors and other stored charges before allowing access. Interlock switches must not be bypassed to allow operation with access doors open.
RF Radiation
Personnel must not be exposed to excessive RF radiation. All RF connectors must be correctly fitted before operation so that no leakage of RF energy can occur and the RF output must be coupled efficiently to the load. It is particularly dangerous to look into open waveguide or coaxial feeders while the device is energised. Screening of the cathode sidearm of high power magnetrons may be necessary.
X-Ray Radiation
High voltage magnetrons emit a significant intensity of X-rays not only from the cathode sidearm but also from the output waveguide. These rays can constitute a health hazard unless adequate shielding for X-ray radiation is provided. This is a characteristic of all magnetrons and the X-rays emitted correspond to a voltage much higher than that of the anode