-
Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
Hs-2000 Ultrasonic Level Meter Intelligent External Water Tank Meter Gauge IP66
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xPower Suppply | 24V DC/240V AC | Power | 10 W |
---|---|---|---|
Protection Class | IP66 | Ambient Temperature | -30~70℃ |
High Light | Hs-2000 Ultrasonic Level Meter,Ultrasonic Level Meter IP66,external Water Tank Meter Gauge IP66 |
Made in China Hs-2000 intelligent external ultrasonic level meter
Overview
Hs-2000 intelligent external type ultrasonic level meter (referred to as "external measurement level meter") can be in the tank outside the continuous measurement of liquid level, but also especially suitable for closed container in a variety of toxic substances, strong acid, strong alkali and all kinds of pure liquid level measurement, the instrument adopts flameproof design, can be used in the need of explosion-proof occasions.
Specification
Output singnal | 4-20mA |
Power | 10w |
Communication interface | RS-485 |
Environmental humidity | 15%~100%RH |
Weight | 3.4kgs |
IP Rating | IP66 |
Working principle
Hs-2000 external ultrasonic level meter using sonar echo ranging principle, to overcome the impact of the tank wall on the ultrasonic signal, using digital signal processing technology, can truly achieve non-contact, measuring tank level. The level meter can output 4~20mA standard signal or output the measurement results to the upper computer (or secondary table) through the RS-485 interface to meet the automatic control of the system.
Product Advantage
NO.1 Non-contact measuring function
ultrasonic sensor (probe) is external, no need to open the measured container
NO.2 automatic calibration
level gauge with self-calibration function, to overcome the traditional level gauge after a long time of use, the accuracy of the problem
NO.3 infrared online debugging function
convenient infrared debugging function, especially suitable for dangerous occasions should not open the cover debugging occasions; At the same time, the difficulty of debugging is reduced
NO.4 self-diagnosis
level gauge has the diagnostic function of its own working state, but also has the hardware diagnostic function; This increases the reliability and stability of the level gauge
NO.5 One-click Recovery
When the level meter is abnormal, you can use the debugger to restore the level meter to the normal state with one click
NO.6 local display and remote transmission function
level meter can be convenient to display the liquid level value in the field, and can be transmitted to the control room through the signal line
Application condition
1. Medium purity
- Liquid can not be filled with dense bubbles in the
- Liquid can not suspend a large number of solid, such as crystal
- Tank bottom can not deposit a large amount of sediment
2. Material of the container to be tested: carbon steel, stainless steel, various metals, glass, epoxy resin, hard plastic, ceramic, glass, hard rubber or composite materials
3. Tank type: spherical tank horizontal tank tank vertical tank and so on
4. Probe installation requirements
- For iron containers, the end face of the probe can be coated with silicone grease and directly attached to the bottom of the container with a magnetic chuck. If the container shell is glass and other materials, you can use glue to stick the probe fixed or fixed at the bottom of the container with a bracket probe pointing to the measured distance in the same straight line
- The probe is directly above the coil and other shielding
- Keep away from the liquid inlet at the bottom of the tank to avoid the impact of the violent flow of the liquid on the measurement
- Keep away from the bottom of the tank top inlet to avoid the impact of the inlet to affect the measurement of the liquid level fluctuations
- Higher than the outlet or sewage outlet to avoid long-term sediment at the bottom of the tank adversely affecting the measurement. If conditions are not met, measures should be taken to ensure regular removal of sediment at the bottom of the tank