Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
Industrial Environments Wika Pressure Transmitter A-10 Measuring Medium Gases / Liquids OEM ODM

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xBrand | Wika | Type | A-10 |
---|---|---|---|
Warranty | 1 Year | Color | Black |
Place Of Origin | Hunan, China | Customized Support | OEM, ODM |
Model Number | QTQ301-J | Pressure Range | 25~2500bar |
Measuring Medium | Gases, Liquids Compatible With 17-4PH Stainless Steel | Sensor Technology | Sputtered Thin Film Sensor |
Overload | 200%F.S/300%F.S | Burst Pressure | 4000%/1000% And ≤400MPa |
Highlight | A-10 wika pressure transmitter,Industrial Environments pressure transmitter |
: High-quality pressure transmitter for general industrial applications; model S-20; see data sheet PE 81.61 Pressure sensor with IO-Link; model A-1200; see data sheet PE 81.90 WIKA data sheet PE 81.60 ∙ 05/2023 Pressure transmitter For general industrial applications Model A-10 Description The field-proven model A-10 pressure transmitter (pressure sensor) is the all-rounder for pressure measurement in industrial environments. Compactly built, it can be integrated into a wide range of machine designs. The many measuring ranges, and special measuring ranges, contribute to its universal applicability. Excellent quality and proven technology Our many years of experience and precise knowledge of customer needs have been incorporated into the development of the model A-10. It has been proving itself in countless applications for over ten years. The consistently high quality and its reliable function are appreciated worldwide and regularly confirmed by both internal and external audits. This bestseller can tolerate up to 100 million load cycles with almost constant precision. Exceptionally large variety covers almost all applications Depending on the requirement, the model A-10 measures Applications ■ Machine building ■ Measurement and control technology ■ Hydraulics and pneumatics ■ Pumps and compressors ■ Shipbuilding
Specifications Optionally the model A-10 is available with an improved non-linearity. Depending on the selected non-linearity the following values result: Accuracy specifications Non-linearity ≤ ±0.5 % of span Non-linearity ≤ ±0.25 % of span Non-linearity per BFSL per IEC 61298-2 Measuring range ≤ 0.1 bar [≤ 1.45 psi] ≤ ±0.5 % of span - Measuring range > 0.1 bar [> 1.45 psi] ≤ ±0.5 % of span ≤ ±0.25 % of span 1) Accuracy → See “Max. measured error per IEC 61298-2” Max. measured error per IEC 61298-2 Measuring range ≥ 0.6 bar [≥ 8.7 psi] ≤ ±1 % of span ≤ ±0.5 % of span Measuring range ≥ 0.4 bar [≥ 5.8 psi] ≤ ±1.2 % of span ≤ ±0.7 % of span Measuring range ≥ 0.25 bar [≥ 3.6 psi] ≤ ±1.3 % of span ≤ ±0.8 % of span Measuring range ≥ 0.16 bar [≥ 2.3 psi] ≤ ±1.5 % of span ≤ ±1 % of span Measuring range ≥ 0.1 bar [≥ 1.45 psi] ≤ ±1.8 % of span - Measuring range ≥ 0.05 bar [≥ 0.73 psi] ≤ ±2.4 % of span - Zero point error 2) 3) 4 ... 20 mA / DC 1 ... 5 V / DC 0.5 ... 4.5 V / DC 0.5 ... 4.5 V ratiometric ≤ ±0.3 % of span ≤ ±0.2 % of span DC 0 ... 10 V ≤ ±0.5 % of span ≤ ±0.4 % of span DC 0 ... 5 V 4) ≤ ±0.6 % of span - 1) Not possible with output signal DC 0 ... 5 V. 2) Measuring ranges ≤ 0.1 bar [≤ 1.45 psi] (or equivalent) only possible with ≤ ±0.5 % of span. 3) Outside reference conditions, add the temperature hysteresis for measuring ranges < 0.6 bar [< 8.7 psi]. 4) Not possible with measuring ranges ≤ 0.1 bar [≤ 1.45 psi] (or equivalent). In case of occasional faults due to electrostatic discharges, a temporary additional measured error of up to ±2.5 % can occur.
Accuracy | ±0.25%F.S |
Output | 4-20mA |
Power supply | 8-32VDC/5VDC |