xType | Temperature Transmitter | Measuring Principle | Head Transmitter |
---|---|---|---|
Input | 2 X RTD, TC | Output | 1 X Analog 4...20 MA / HART |
Auxiliary Power Supply | 11...42 V DC | Communication | HART-protocol |
Certification | CE | Weight | 40 To 50 G (1.4 To 1.8 Oz) |
Supply Voltage | 11 V ≤ Vcc ≤ 42 V | Condition | Original And New |
High Light | TMT82 Temperature Head Transmitter,Temperature Head Transmitter 20 mA,Head Temperature Transmitter Sensor |
Endress + Hauser ITEMP TMT82 TMT182 Temperature Transmitter
TMT72 Hart Thermocouple Temperature Sensor TMT84-A1A2A TMT142-A113
Application
• Two input channels and HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal
• The iTEMP TMT82 is characterized by its reliability, longterm stability, high precision and advanced diagnostic function (important in critical processes)
• For the highest level of safety, reliability and risk reduction
• Universal input for resistance thermometers (RTD), thermocouples (TC), resistance transmitters (Ω) and voltage transmitters (mV)
• Installation in terminal head form B (flat face)
• Optional: installation in field housing for Ex d applications
• Optional: device design for DIN rail mounting
• Optional: installation in field mount housing with separate terminal compartment and plug-on display
Your benefits
• Safe operation in hazardous locations due to international approvals
• SIL certification as per IEC 61508:2010
• High accuracy of measuring point through sensortransmitter matching
• Reliable operation with sensor monitoring and device hardware fault recognition
• Diagnostics information according to NAMUR NE107
• Several mounting versions and sensor connection combinations
• Fast connection thanks to push-in terminal technology, optional
• Write protection for device parameters