SERIES 2000 MAGNEHELIC® DIFFERENTIAL PRESSURE GAGES

Indicate Positive, Negative or Differential, Accurate within 1%

 

  • No Power Required
  • Low Cost
  • Used in Isolation/ Hospital Environments and Temporary Units (no power required)

Select the Series 2000 Magnehelic® Gage for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from. Using Dwyer’s simple, frictionless Magnehelic® gage movement, it quickly indicates air or noncorrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator. Also included with the –HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.

NIST CALIBRATION available in Product Configurator.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Please see Series AT-2000 for ATEX approved.

California Residents: Click Here for Proposition 65 WARNING.

PRODUCT APPLICATIONS

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

 

SERIES 2000 MAGNEHELIC® DIFFERENTIAL PRESSURE GAGES

Indicate Positive, Negative or Differential, Accurate within 1%

 

  • No Power Required
  • Low Cost
  • Used in Isolation/ Hospital Environments and Temporary Units (no power required)

Select the Series 2000 Magnehelic® Gage for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from. Using Dwyer’s simple, frictionless Magnehelic® gage movement, it quickly indicates air or noncorrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator. Also included with the –HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.

NIST CALIBRATION available in Product Configurator.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Please see Series AT-2000 for ATEX approved.

California Residents: Click Here for Proposition 65 WARNING.

PRODUCT APPLICATIONS

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

 

SERIES 2000 MAGNEHELIC® DIFFERENTIAL PRESSURE GAGES

Indicate Positive, Negative or Differential, Accurate within 1%

 

  • No Power Required
  • Low Cost
  • Used in Isolation/ Hospital Environments and Temporary Units (no power required)

Select the Series 2000 Magnehelic® Gage for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from. Using Dwyer’s simple, frictionless Magnehelic® gage movement, it quickly indicates air or noncorrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator. Also included with the –HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.

NIST CALIBRATION available in Product Configurator.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Please see Series AT-2000 for ATEX approved.

California Residents: Click Here for Proposition 65 WARNING.

PRODUCT APPLICATIONS

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

 

Model Description
2000-0 Differential pressure gage, range 0-0.50" w.c., minor divisions .01, calibrated for vertical scale position.
2000-00 Differential pressure gage, range 0-0.25" w.c., minor divisions .005, calibrated for vertical scale position.
2000-00N Differential pressure gage, range .05-0-.2" w.c., minor divisions .005, calibrated for vertical scale position.
2001 Differential pressure gage, range 0-1.0" w.c., minor divisions .02.
2002 Differential pressure gage, range 0-2.0" w.c., minor divisions .05.
2003 Differential pressure gage, range 0-3.0" w.c., minor divisions .10.
2004 Differential pressure gage, range 0-4.0" w.c., minor divisions .10.
2005 Differential pressure gage, range 0-5.0" w.c., minor divisions .10.
2006 Differential pressure gage, range 0-6.0" w.c., minor divisions .20.
2008 Differential pressure gage, range 0-8.0" w.c., minor divisions .20.
2010 Differential pressure gage, range 0-10" w.c., minor divisions .20.
2015 Differential pressure gage, range 0-15" w.c., minor divisions .50.
2020 Differential pressure gage, range 0-20" w.c., minor divisions .50.
2025 Differential pressure gage, range 0-25" w.c., minor divisions .50.
2030 Differential pressure gage, range 0-30" w.c., minor divisions 1.0.
2040 Differential pressure gage, range 0-40" w.c., minor divisions 1.0.
2050 Differential pressure gage, range 0-50" w.c., minor divisions 1.0.
2060 Differential pressure gage, range 0-60" w.c., minor divisions 2.0.
2080 Differential pressure gage, range 0-80" w.c., minor divisions 2.0.
2100 Differential pressure gage, range 0-100" w.c., minor divisions 2.0.
2150 Differential pressure gage, range 0-150" w.c., minor divisions 5.0.

 

Service:
Air and non-combustible, compatible gases (natural gas option available). Note: May be used with hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.
Wetted Materials:
Consult factory.
Housing:
Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 hour salt spray corrosion test.
Accuracy:
±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100PA, -125PA, -10MM and ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C).
Pressure Limits:
-20 in Hg. to 15 psig. (-0.677 bar to 1.034 bar); MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52 bar).
Enclosure Rating:
IP67.
Overpressure:
Relief plug opens at approximately 25 psig (1.72 bar), standard gages only. See Overpressure Protection note on Catalog page.
Temperature Limits:
20 to 140°F (-6.67 to 60°C). -20°F (-28°C) with low temperature option.
Size:
4" (101.6 mm) diameter dial face.
Mounting Orientation:
Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections:
1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back.
Weight:
1 lb 2 oz (510 g); MP & HP 2 lb 2 oz (963 g).
Standard Accessories:
Two 1/8" NPT plugs for duplicate pressure taps, two 1/8" pipe thread to rubber tubing adapters and three flush mounting adapterswith screws. (Mounting and snap ring retainer substituted for three adapters in MP & HP gage accessories.)
Agency Approval:
Meets the technical requirements of EU Directive 2011/65/EU (RoHS II). Note: -SP models not RoHS approved.