New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
| GENERAL | ||
| MEASUREMENT CHANNELS | 5 X OPTICAL CHANNELS; 1 X SMART ELECTRODE CHANNEL (pH MEASUREMENT) | |
| Absorbance Range | 0.000Abs-4.000Abs | |
| Absorbance Resolution | 0.001 Abs | |
| Absorbance Accuracy | ±0.003 Abs (at 1.000 Abs) | |
| Absorbance Light Source | Light-emitting diode | |
| Absorbance Bandpass Filter Bandwidth | 8nm | |
| Absorbance Bandpass Filter Wavelength Accuracy | ±1.0nm | |
| Light Detector | Silicon photocell | |
| Cuvette Type | round, 24.6 mm diameter | |
| Number of Methods | 128 max | |
| pH Range | -2.00 to 16.00 pH (±1000mV)* | |
| pH Resolution | 0.01 pH (0.01 mV)* | |
| Temperature Compensation | ATC (-5.0 to 100.0°C;*) | |
| Additional Specifications: | ||
| Logging | 1000 readings (mixed photometer and electrode) | |
| Display | 128 x 64 pixel B/W LCD with backlight | |
| USB-A (host) functions | mass-storage host | |
| USB-B ( Device) Functions | power input, mass-storage device | |
| Battery Life | >500 Photometer measurements, or 50 hours of continuous pH measurement | |
| Power supply | 5 VDC USB 2.0 power adapter/ type micro-B connector 3.7 VDC Li-polymer rechargeable battery, non-serviceable | |
| Environment | 0 to 50°C; 0 to 95% RH, non-condensing | |
| Dimensions | 206 x 177 x 97mm | |
| Weight | 1.0kg | |
| Ordering Information | HI-83300 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. | |
| *Limits will be reduced to actual sensor limits |
ABSORBANCE
| Absorbance Range | 0.000 to 4.000 Abs | |
| Absorbance Resolution | 0.001 Abs | |
| Absorbance Accuracy | +/-0.003Abs @ 1.000 Abs |
ALKALINITY - Reagents - HI-93755-01 (100 tests); HI-93755-03 (300 tests)
| Alkalinity Range | Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3) | |
| Alkalinity Resolution | 1 mg/L | |
| Alkalinity Accuracy | ±5 mg/L ±5% of reading | |
| Alkalinity Method | Colorimetric method |
ALUMINIUM - Reagents - HI-93712-01 (100 tests); HI-93712-03 (300 tests)
| Aluminium Range | 0.00 to 1.00 mg/L (as Al3+) | |
| Aluminium Resolution | 0.01 mg/L | |
| Aluminium Accuracy | ±0.04 mg/L ±4% of reading | |
| Aluminium Method | Adaptation of the aluminon method |
AMMONIA - Reagents: HR - HI-93733-01 (100 tests); HI-93733-03 (300 tests)
MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests)
LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)
| Ammonia Range | Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N) | |
| Ammonia Resolution | 0.01 mg/L; 0.1 mg/L | |
| Ammonia Accuracy | Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C | |
| Ammonia Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
ANIONIC SURFACTANTS
| Anionic Surfactants Range | 0.00 to 3.50 mg/L (as SDBS) | |
| Anionic Surfactants Resolution | 0.01 mg/L | |
| Anionic Surfactants Accuracy | ±0.04 mg/L ±3% of reading | |
| Anionic Surfactants Method | Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS. |
BROMINE - Reagents: HI-93716-01 (100 tests); HI-93716-03 (300 tests)
| Bromine Range | 0.00 to 8.00 mg/L (as Br2) | |
| Bromine Resolution | 0.01 mg/L | |
| Bromine Accuracy | ±0.08 mg/L ±3% of reading | |
| Bromine Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. |
CALCIUM - Reagents: HI-937521-01 (50 tests); HI-937521-03 (150 tests)
| Calcium Range | Freshwater: 0 to 400 mg/L (as Ca2+) Seawater: 200 to 600 mg/L (as Ca2+) | |
| Calcium Resolution | 1 mg/L | |
| Calcium Accuracy | Freshwater: ±10 mg/L ±5% of reading Seawater: ±6% of reading | |
| Calcium Method | Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method |
CHLORIDE - Reagents: HI-93753-01 (100 tests); HI-93753-03 (300 Tests)
| Chloride Range | 0.0 to 20.0 mg/L (as Cl⁻) | |
| Chloride Resolution | 0.1 mg/L | |
| Chloride Accuracy | ±0.5 mg/L ±6% of reading at 25 °C |
CHLORINE DIOXIDE - Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)
| Chlorine Dioxide Range | 0.00 to 2.00 mg/L (as ClO2) | |
| Chlorine Dioxide Resolution | 0.01 mg/L | |
| Chlorine Dioxide Accuracy | ±0.10 mg/L ±5% of reading | |
| Chlorine Dioxide Method | Adaptation of the Chlorophenol Red method. |
CHLORINE - Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine UHR Reagents: HI-95771-01 (100 tests); HI-95771-03 (300 tests)
Chlorine, Free and Total HR: HI-93734-01 (100 tests); HI-93734-03 (300 tests)
Chlorine, Free ULR: HI-95762-01 (100 tests); HI-95762-03 (300 tests)
Chlorine Total: HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)
| Free Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) | |
| Free Chlorine Resolution | 0.01 mg/L Ultra Low Range: 0.001 mg/L | |
| Free Chlorine Accuracy | ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading | |
| Total Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) Ultra High Range: 0 to 500 mg/L (as Cl2) | |
| Total Chlorine Resolution | 0.01 mg/L; 0.001 mg/L; 1 mg/L | |
| Total Chlorine Accuracy | ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading Ultra High Range: ±3 mg/L ±3% of reading | |
| Chlorine Method | Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl |
CHROMIUM, HEXAVALENT - Reagents: HR - HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR - HI-93749-01 (100 tests); HI-93749-03 (300 tests)
| Chromium, Hexavalent Range | Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+) | |
| Chromium, Hexavalent Resolution | 1 μg/L | |
| Chromium, Hexavalent Accuracy | Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading | |
| Chromium, Hexavalent Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method. |
COLOUR, WATER
| Colour, Water Range | 0 to 500 PCU (Platinum Cobalt Units) | |
| Colour, Water Resolution | 1 PCU | |
| Colour, Water Accuracy | ±10 PCU ±5% of reading | |
| Colour, Water Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method. |
COPPER - Reagents: HR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper - HI-93702T - 01 (100 tests); HI-93702T-03 (300 tests)
LR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)
| Copper Range | Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+) | |
| Copper Resolution | 0.001 mg/L; 0.01 mg/L | |
| Copper Accuracy | Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading | |
| Copper Method | Adaptation of the EPA bicinchoninate method |
CYANURIC ACID - Reagents: HI-93722-01 (100 tests); HI-93722-03 (300 tests)
| Cyanuric Acid Range | 0 to 80 mg/L (as CYA) | |
| Cyanuric Acid Resolution | 1 mg/L | |
| Cyanuric Acid Accuracy | ±1 mg/L ±15% of reading | |
| Cyanuric Acid Method | Adaptation of the turbidimetric method |
FLUORIDE - Reagents: HR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)
LR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)
| Fluoride Range | Low Range: 0.00 to 2.00 mg/L (as F-) High range: 0.0 to 20.0 mg/L (as F-) | |
| Fluoride Resolution | 0.01 mg/L; 0.1 mg/L | |
| Fluoride Accuracy | Low Range: ±0.03 mg/L ±3% of reading High Range: ±0.5 mg/L ±3% of reading | |
| Fluoride Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method |
HARDNESS, CALCIUM - Reagents: HI-93720-01 (100 tests); HI-93720-03 (300 tests)
| Hardness, Calcium Range | 0.00 to 2.70 mg/L (as CaCO3) | |
| Hardness, Calcium Resolution | 0.01 mg/L | |
| Hardness, Calcium Accuracy | ±0.11 mg/L ±5% of reading | |
| Hardness, Calcium Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method |
HARDNESS, MAGNESIUM - Reagents: HI-93719-01 (100 tests); HI-93719-03 (300 tests)
| Hardness, Magnesium Range | 0.00 to 2.00 mg/L (as CaCO3) | |
| Hardness, Magnesium Resolution | 0.01 mg/L | |
| Hardness, Magnesium Accuracy | ±0.11 mg/L ±5% of reading | |
| Hardness, Magnesium Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method |
HARDNESS, TOTAL - Reagents: HR - HI-93735-02 (100 tests); MR - HI-93735-01 (100 tests); LR - HI-93735-00 (100 tests); HR MR &LR - HI-93735-0 (100 x 3 tests)
| Hardness, Total Range | Low Range: 0 to 250 mg/L (as CaCO3) Medium Range: 200 to 500 mg/L (as CaCO3) High Range: 400 to 750 mg/L (as CaCO3) | |
| Hardness, Total Resolution | 1 mg/L | |
| Hardness, Total Accuracy | Low Range: ±5 mg/L ±4% of reading Medium Range: ±7 mg/L ±3% of reading High Range: ±10 mg/L ±2% of reading | |
| Hardness, Total Method | Adaptation of the EPA recommended method 130.1 |
HYDRAZINE - Reagents: HI-93704-01 (100 tests); HI-93704-03 (300 tests)
| Hydrazine Range | 0 to 400 μg/L (as N2H4) | |
| Hydrazine Resolution | 1 μg/L | |
| Hydrazine Accuracy | ±4% of full scale reading | |
| Hydrazine Method | Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method |
IODINE - Reagents: HI-93718-01 (100 tests); HI-93718-03 (300 tests)
| Iodine Range | 0.0 to 12.5 mg/L (as I2) | |
| Iodine Resolution | 0.1 mg/L | |
| Iodine Accuracy | ±0.1 mg/L ±5% of reading | |
| Iodine Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method |
IRON - Reagents: HR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)
LR - HI-93746-01 (50 tests); HI-93746-03 (150 tests)
| Iron Range | Low Range: 0.000 to 1.600 mg/L (as Fe) High Range: 0.00 to 5.00 mg/L (as Fe) | |
| Iron Resolution | 0.001 mg/L; 0.01 mg/L | |
| Iron Accuracy | Low Range: ±0.01 mg/L ±8% of reading High Range: ±0.04 mg/L ±2% of reading | |
| Iron Method | Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters |
MAGNESIUM - Reagents: HI-937520-01 (50 tests); HI-937520-03 (150 tests)
| Magnesium Range | 0 to 150 mg/L (as Mg2+) | |
| Magnesium Resolution | 1 mg/L | |
| Magnesium Accuracy | ±5 mg/L ±3% of reading | |
| Magnesium Method | Adaptation of the Calmagite method |
MANGANESE - Reagents: HR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)
LR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)
| Manganese Range | Low Range: 0 to 300 µg/L (as Mn) High range: 0.0 to 20.0 mg/L (as Mn) | |
| Manganese Resolution | 1 µg/L; 0.1 mg/L | |
| Manganese Accuracy | Low Range: ±0.02 mg/L ±3% of reading High Range: ±0.3 mg/L ±5% of reading | |
| Manganese Method | Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method |
MOLYBDENUM - Reagents: HI-93730-01 (100 tests); HI-93730-03 (300 tests)
| Molybdenum Range | 0.0 to 40.0 mg/L (as Mo6+) | |
| Molybdenum Resolution | 0.1 mg/L | |
| Molybdenum Accuracy | ±0.3 mg/L ±5% of reading | |
| Molybdenum Method | Adaptation of the mercaptoacetic acid method |
NICKEL - Reagents: HR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)
| Nickel Range | Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni) | |
| Nickel Resolution | 0.001 mg/L; 0.01 g/L | |
| Nickel Accuracy | Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading | |
| Nickel Method | Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method |
NITRATE - Reagents: HI-93728-01 (100 tests); HI-93728-03 (300 tests)
| Nitrate Range | 0.0 to 30.0 mg/L (as NO3-- N) | |
| Nitrate Resolution | 0.1 mg/L | |
| Nitrate Accuracy | ±0.5 mg/L ±10% of reading | |
| Nitrate Method | Adaptation of the cadmium reduction method |
NITRITE - Reagents: HR - HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR - HI-93707-01 (100 tests); HI-93707-03 (300 tests)
| Nitrite Range | Freshwater Low Range: 0 to 600 μg/L (as NO2--N) High Range: 0 to 150 mg/L (as NO2-) Seawater Ultra Low Range: 0 to 200 μg/L (as NO2--N) | |
| Nitrite Resolution | Freshwater: 1 μg/L; 1 mg/L Seawater: 1 μg/L | |
| Nitrite Accuracy | Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Seawater ±10 μg/L ±4% of reading | |
| Nitrite Method | Adaptation of the EPA Diazotization method 354.1 |
OXYGEN, DISSOLVED - Reagents: HI-93732-01 (100 tests); HI-93732-03 (300 tests)
| Oxygen, Dissolved Range | 0.0 to 10.0 mg/L (as O2) | |
| Oxygen, Dissolved Resolution | 0.1 mg/L | |
| Oxygen, Dissolved Accuracy | ±0.4 mg/L ±3% of reading | |
| Oxygen, Dissolved Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method |
OXYGEN, SCAVENGER
| Oxygen, Scavenger Range | 0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid) | |
| Oxygen, Scavenger Resolution | 1 μg/L (DEHA); 0.01 mg/L | |
| Oxygen, Scavenger Accuracy | ±5 μg/L ±5% of reading (DEHA) | |
| Oxygen, Scavenger Method | Adaptation of the iron reduction method |
OZONE - Reagents: HI-93757-01 (100 tests); HI-93757-03 (300 tests)
| Ozone Range | 0.00 to 2.00 mg/L (as O3) | |
| Ozone Resolution | 0.01 mg/L | |
| Ozone Accuracy | ±0.02 mg/L ±3% of reading | |
| Ozone Method | Colorimetric DPD Method |
pH - Reagents: HI-93710-01 (100 tests); HI-93710-03 (300 tests)
| pH Range | Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH | |
| pH Resolution | Photometer: 0.1 pH pH electrode: 0.1 pH | |
| pH Accuracy | Photometer: ±0.1 pH pH electrode: ±0.01 pH | |
| pH Calibration | Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) | |
| pH Temperature Compensation | Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used | |
| pH CAL Check (electrode diagnostics) | clean electrode and check buffer/check probe displayed during calibration | |
| pH Method | Photometer: phenol red | |
| pH-mV Range | ±1000 mV | |
| pH-mV Resolution | 0.1 mV | |
| pH-mV Accuracy | ±0.2 mV |
PHOSPHATE - Reagents: HR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)
| Phosphate Range | Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P) | |
| Phosphate Resolution | Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L | |
| Phosphate Accuracy | Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading | |
| Phosphate Method | Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method |
POTASSIUM - Reagents: HI-93750-01 (100 tests); HI-93750-03 (300 tests)
| Potassium Range | 0.0 to 20.0 mg/L (as K) | |
| Potassium Resolution | 0.1 mg/L | |
| Potassium Accuracy | ±3.0 mg/L ±7% of reading | |
| Potassium Method | Adaptation of the Turbidimetric Tetraphenylborate method |
SILICA - Reagents: HR - HI-96770-01 (100 tests); HI-96770-03 (300 tests)
LR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)
| Silica Range | Low Range: 0.00 to 2.00 mg/L (as SiO2) High Range: 0 to 200 mg/L (as SiO2) | |
| Silica Resolution | 0.01 mg/L; 1 mg/L | |
| Silica Accuracy | Low Range: ±0.03 mg/L ±3% of reading High Range: ±1 mg/L ±5% of reading | |
| Silica Method | Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2 |
SILVER - Reagents: HI-93737-01 (50 tests); HI-93737-03 (150 tests)
| Silver Range | 0.000 to 1.000 mg/L (as Ag) | |
| Silver Resolution | 0.001 mg/L | |
| Silver Accuracy | ±0.020 mg/L ±5% of reading | |
| Silver Method | Adaptation of the PAN method |
SULPHATE - Reagents: HI-93751-01 (100 tests); HI-93751-03 (300 tests)
| Sulphate Range | 0 to 150 mg/L (as SO42-) | |
| Sulphate Resolution | 1 mg/L | |
| Sulphate Accuracy | ±5 mg/L ±3% of reading | |
| Sulphate Method | Turbidimetric - Sulphate is precipitated with barium chloride crystals |
ZINC - Reagents: HI-93731-01 (100 tests); HI-93731-03 (300 tests)
| Zinc Range | 0.00 to 3.00 mg/L (as Zn) | |
| Zinc Resolution | 0.01 mg/L | |
| Zinc Accuracy | ±0.03 mg/L ±3% of reading |