Output Type | 2-wire | Rated Operating Distance | 1.5 Mm |
---|---|---|---|
Installation | Flush | ||
Highlight | 2-wire Inductive Sensor,NJ1 Inductive Sensor,1.5 mm Inductive Sensor |
Product Description
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 0.97 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 0.1 mm | |
Current consumption | ||
Measuring plate not detected | min. 2.5 mA | |
Measuring plate detected | ≤ 1.2 mA | |
Functional safety related parameters | ||
MTTFd | 11467 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2 |