x| Measuring Voltage Range | 600v | Place Of Origin | China | 
|---|---|---|---|
| Brand Name | FLUKE | Model Number | FLUKE-110/CN | 
| Single Package Size | 10X10X10 Cm | Single Gross Weight | 0.500 Kg | 
| Highlight | New FLUKE 110 Digital Multimeter,Original FLUKE 110 Digital Multimeter,600V FLUKE 110 Digital Multimeter | ||
Product overview: Fluke 110 True-rms Digital Multimeter
Compact true-rms meter for accurate electrical installation and troubleshooting
The Fluke 110 is a versatile multimeter for electrical measurements and troubleshooting. Trusted by residential and commercial electricians for troubleshooting and maintenance. The 110 is for professional use, where true-rms accuracy is needed.
Key product capabilities
- True-rms ac voltage for accurate measurements on non-linear signals
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
- 
	Specifications: Fluke 110 True-rms Digital MultimeterAccuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] ) General specifications Maximum voltage (between any terminal and earth ground) 600V Safety IEC 61010-1, Pollution degree 2 
 IEC 61010-2-033, CAT III 600 VDisplay Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Temperature 
 Operating
 Storage
 -10 °C to + 50 °C
 -40 °C to + 60 °CBattery 9 volt Alkaline, IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 DC volts 6.000 V 
 60.00 V
 600.0 V0.001 V 
 0.01 V
 0.1 V0.5 % + 2 
 1All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.Accuracy Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 
 2.0 % + 3 (500 Hz to 1 kHz)AC volts1 true-rms 6.000 V 
 60.00 V
 600.0 V0.001 V 
 0.01 V
 0.1 V1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Continuity 600 Ω 1 Ω Beeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer. Ohms 600.0 Ω 0.1 Ω 0.9 % + 2 6.000 kΩ 
 60.00 kΩ
 600.0 kΩ
 6.000 MΩ0.001 kΩ 
 0.01 kΩ
 0.1 kΩ
 0.001 MΩ0.9 % + 1 40.00 MΩ 0.01 MΩ 5 % + 2 
 


 
                         
                         
                         
                         
                         
                         
                         
                         
                         
                        