Dwyer USA Model 2060 Magnehelic Gage Differential Pressure Gauge 0-60 Inch WC
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xConnection | 1/8 NPT | Weight | 0.55kg |
---|---|---|---|
Temperature Limits | 20 To 140°F | Accuracy | ±2% Of FS |
Size | 114.3*139.7mm | ||
Highlight | Dwyer USA Differential Pressure Gauge,Dwyer 2060 Differential Pressure Gauge,60 Inch WC Differential Pressure Gauge |
Introduction
Dial differential pressure gauges measure the difference in pressure between two points in a system and display the measurement on an analog dial display. Users can connect gauges with integral switches to a control system to respond when the measured pressure rises or falls below a set point. Gauges are available for use in low-, medium-, and high-pressure systems.
Specification
Connection | 1/8 NPT |
Weight | 0.55kg |
Temperature Limits | 20 to 140°F |
Accuracy | ±2% of FS |
Size | 114.3*139.7mm |
Working principle
Based on the sensing element using two identical stiffness of the bellows, therefore under the same measured medium forced it to produce the same focus respectively on the legs, because of the spring leaf waiting for a moment on both sides do not produce the deflection, stent is still in the original position, the gear transmission mechanism is not action,
make the pointer still refers to the zero When applying different pressure (general high pressure end is higher than low pressure end), the force of two bellows acting on the movable bracket is not equal, so that the corresponding displacement is produced respectively, and drive the gear transmission mechanism to drive and to enlarge, indicating the differential pressure between the two after the pointer is deflect.
Performance characteristic
• Easy to read gage through undistorted plastic face permits viewing from far away
• Patented design provides quick response to pressure changes means no delay in assessing critical situations
• Durable and rugged housing and high-quality components combine to provide long service life and minimized down-time
• High accuracy option is twice as accurate as the standard Magnehelic® gage
Application areas: