Dwyer Series LCD Digital Differential Pressure Transducer MS-021

Place of Origin USA
Brand Name Dwyer
Certification CE
Model Number MS-021 MS-111-LCD
Minimum Order Quantity 1
Price USD$80/PC
Packaging Details Carton
Delivery Time 5-10 Work days
Payment Terms D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 500

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Accuracy ±1% Stability ±1% FS/year
Temperature Limits 0 To 150°F (-18 To 66°C) Pressure Limits 1 Psi Maximum, Operation; 10 Psi, Burst
Power Requirements 10 To 35 VDC (2-wire); 17 To 36 VDC Or Isolated 21.6 To 33 VAC (3-wire) Output Signals 4 To 20 MA (2-wire); 0 To 5 V, 0 To 10 V (3-wire)
High Light

Digital Differential Pressure Transducer

,

LCD Differential Pressure Transducer

,

MS-021 Differential Pressure Transmitter

You can tick the products you need and communicate with us in the message board.
Service Air and non-combustible compatible gases
Response Time 300 ms
Zero & Span Adjustments Digital push button
Loop Resistance Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ
Current Consumption 40 mA max
Display (optional) 4 digit LCD
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Diaphragm in vertical position
Weight 8.0 oz (230 g)
Leave a Message
Service Air and non-combustible compatible gases
Product Description

Dwyer Series MS MAGNESENSE Diffirential Pressure Transmitter MS-021 MS-111-LCD Digital Differential Pressure Transducer

 

The Series MS Magnesense® Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure and air velocity. This compact package is loaded with features such as, field selectable English or metric ranges, field upgradeable LCD display, adjustable dampening of output signal (with optional display) and the ability to select a square root output for use with Pitot tubes and other similar flow sensors.

Along with these features, the patented magnetic sensing technology provides exceptional long term performance and enables the Magnesense® Differential Pressure Transmitter to be the single solution for your pressure and flow applications.

Model Description
MS-021 Differential pressure transmitter, 4-20 mA output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount.
MS-021-LCD Differential pressure transmitter, 4-20 mA output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD.
MS-111 Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount.
MS-111-LCD Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD.
MS-112 Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount.
MS-112-LCD Differential pressure transmitter, 4-20 mA output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD.
MS-121 Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount.
MS-121-LCD Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD.
MS-122 Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount.
MS-122-LCD Differential pressure transmitter, 4-20 mA output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD.
MS-131 Differential pressure transmitter, 4-20 mA output, selectable range 10" w.c. (2 kPa), wall mount.
MS-131-LCD Differential pressure transmitter, 4-20 mA output, selectable range 10" w.c. (2 kPa), wall mount, with LCD.
MS-141 Differential pressure transmitter, 4-20 mA output, selectable range 15" w.c. (3 kPa), wall mount.
MS-141-LCD Differential pressure transmitter, 4-20 mA output, selectable range 15" w.c. (3 kPa), wall mount, with LCD.
MS-151 Differential pressure transmitter, 4-20 mA output, selectable range 25" w.c. (5 kPa), wall mount.
MS-151-LCD Differential pressure transmitter, 4-20 mA output, selectable range 25" w.c. (5 kPa), wall mount, with LCD.
MS-221 Differential pressure transmitter, 0-10 V output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount.
MS-221-LCD Differential pressure transmitter, 0-10 V output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD.
MS-311 Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount.
MS-311-LCD Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD.
MS-312 Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount.
MS-312-LCD Differential pressure transmitter, 0-10 V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD.
MS-321 Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount.
MS-321-LCD Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD.
MS-322 Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount.
MS-322-LCD Differential pressure transmitter, 0-10 V output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD.
MS-621 Differential pressure transmitter, 5 VDC output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount.
MS-621-LCD Differential pressure transmitter, 5 VDC output, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD.
MS-711 Differential pressure transmitter, 5 VDC output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount.
MS-711-LCD Differential pressure transmitter, 5 VDC output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD.
MS-712-LCD Differential pressure transmitter, 5V output, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD.
MS-721 Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount.
MS-721-LCD Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD.
MS-722-LCD Differential pressure transmitter, 5 VDC output, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD.
MS-821 Differential pressure transmitter, 5V output, 12V input, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount.
MS-821-LCD Differential pressure transmitter, 5V output, 12V input, selectable range ±0.1", 0.25", 0.5" w.c. (±25, 50, 100 Pa), wall mount, with LCD.
MS-911 Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount.
MS-911-LCD Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), wall mount, with LCD.
MS-912 Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount.
MS-912-LCD MS-912 Differential pressure transmitter, 5V output, 12V input, selectable range 1", 2", 5" w.c. (250, 500, 1250 Pa), duct mount, with LCD.
MS-921 Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount.
MS-921-LCD Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), wall mount, with LCD.
MS-922 Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount.
MS-922-LCD Differential pressure transmitter, 5V output, 12V input, selectable range 0.1", 0.25", 0.5" w.c. (25, 50, 100 Pa), duct mount, with LCD.

 

Specifications

 

Service:

Air and non-combustible compatible gases.

Wetted Materials:

Consult factory.

Accuracy:

±1% for 0.25" (50 Pa), 0.5" (100 Pa), 2" (500 Pa), 5" (1250 Pa), 10" (2 kPa), 15" (3 kPa), 25" (5 kPa) ±2% for 0.1" (25 Pa), 1" (250 Pa) and all bidirectional ranges.

Stability:

±1% FS/year.

Temperature Limits:

0 to 150°F (-18 to 66°C).

Pressure Limits:

1 psi maximum, operation; 10 psi, burst.

Power Requirements:

10 to 35 VDC (2-wire); 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).

Output Signals:

4 to 20 mA (2-wire); 0 to 5 V, 0 to 10 V (3-wire).

Response Time:

300 ms.

Zero & Span Adjustments:

Digital push button.

Loop Resistance:

Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ.

Current Consumption:

40 mA max.

Display (optional):

4 digit LCD.

Electrical Connections:

4-20 mA, 2-wire: European Style Terminal Block for 16 to 26 AWG. 0-10 V, 3-wire: European Style Terminal Block 16 to 22 AWG.

Electrical Entry:

1/2" NPS Thread. Accessory: Cable Gland for 5 to 10 mm diameter cable.

Process Connection:

3/16" (5 mm) ID tubing. Maximum OD 9 mm.

Enclosure Rating:

NEMA 4X (IP66).

Mounting Orientation:

Diaphragm in vertical position.

Weight:

8.0 oz (230 g).

Agency Approvals:

CE.

 

Features

  • Field selectable English or Metric ranges
  • Field upgradeable LCD display
  • Adjustable damping of output signal (with optional display)
  • Ability to select a square root output for use with pitot tubes and other similar flow sensors

Options

  • Add -LCD to end of model numbers for units with display
    Example: MS-121-LCD
  • Add -NIST to end of model numbers for NIST Traceable Certificate
    Example: MS-021-NIST
  • Add -FC to end of model numbers for Factory Calibration Certificate
    Example: MS-021-FC
  • Add -DS to end of model number for dessicant cover, (not compatible with LCD option)
    Example: MS-021-DS

Model Chart

EXAMPLE MS 0 2 1 AT Series MS-021-AT Magnesense® Differential Pressure Transmitter, bidirectional unit, 4-20 mA output, low range 0.1, 0.25, 0.5" w.c. & 25, 50, 100 Pa, wall mount, with aluminum tag.
SERIES MS         Magnesense® Differential Pressure Transmitter
OUTPUT   0
1
2
3
6
7
8
9
      Bidirectional Unit, 4-20 mA
Positive Only Unit, 4-20 mA
Bidirectional Unit, 0-10 V
Positive Only Unit, 0-10 V
Bidirectional Unit, 0-5 V
Positive Only Unit, 0-5 V
Bidirectional Unit, 0-5 V Output 0-12VDC Input
Positive Only Unit, 0-5V Output 0-12 VDC Input
RANGE     1
2
3
4
5
    High Range 1, 2, 5" w.c. & 250, 500, 1250 Pa
Low Range 0.1, 0.25, 0.5" w.c. & 25, 50, 100 Pa
Piezo 10" w.c. & 2 kPa
Piezo 15" w.c. & 3 kPa
Piezo 25" w.c. & 5 kPa
MOUNTING       1
2
3
  Wall Mount
Duct Mount
Din Mounting Bracket
OPTIONS         AT
DJE
DJM
DS
GLD
LCD
NIST
ST
WO
Aluminum Tag
Velocity Mode Selectable Decimal Place (English Units)
Velocity Mode Selectable Decimal Place (Metric Units)
Dessicant Cover (not available)
Cable Gland Accessories Pack
Liquid Crystal Display
NIST Calibration Certificate
Stainless Steel Tag
LCD Cover w/o LCD Display

 

Approvals