All Products
-
Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
100% Original New Dangerous Place Limit Switch Unit Weight 6.490409 Ounces
| Unit Weight: | 6.490409 Ounces |
|---|---|
| Class Of Protection: | IP65 |
| Dc Rated Voltage: | 125 Volts DC |
Yokogawa CPU Module SCP451-51-S1 Process Module
| Product Type: | Processor Module |
|---|---|
| Voltage: | 220V |
| Frequency: | 50Hz |
3/2 Valve Operation Norgren Y013AA1H1BS Solenoid Valve with Stainless Steel Materials
| Media: | Compressed Air |
|---|---|
| Operating Temperature: | -50 ... 90 °C, -58 ... 194 °F |
| Operating Pressure: | 0 ... 174 Psi |
100% Original New Sensors That Reduce Machine Downtime And Mechanical Damage
| Thread Size: | M8×1 |
|---|---|
| Switching Frequency: | 4000HZ |
| Shell Length: | 52mm |
100% New Original Aluminum Filter / Regulator Maximum Inlet Pressure 20bar
| Operating Temperature: | -40...80 ℃ |
|---|---|
| Outlet Pressure Regulation: | 0.25...7bar |
| Maximum Inlet Pressure: | 20bar |
100% New Original Detection Contrast Sensor Dimension 12mm*31.5mm*21mm
| Sensing Distance: | ≤12.5mm |
|---|---|
| Inductive Distance Tolerance: | ±3mm |
| Dimension: | 12mmx31.5mmx21mm |
IP54 Enclosure Rating and 2 GB Internal Flash Memory Emerson TREXCHPNA9S1S Trex Device Communicator for Smooth Operation
| Microprocessor: | 800 MHZ ARM Cortex A8/NXP |
|---|---|
| Display: | 5.7 In Color VGA Resistive Touchscreen |
| Battery Operating Time: | 8+ Hours Of Typical Use |
Dwyer Explosion-Proof RTD Temperature Transmitter TTE-104-W-LCD
| Temperature Sensor: | Pt1000, 0.00385 DIN |
|---|---|
| Temperature Limits: | Transmitter: ±0.1% FS; Probe: ±0.3% FS |
| Thermal Drift Effects: | ±0.02%/°C Max |
Dwyer Series CDWP Carbon Dioxide Transmitter CDWP-05W-C1,CDWP-10W-C1
| Sensor: | NDIR |
|---|---|
| Rang: | CO2: 0 To 2000, 0 To 5000, Or 0 To 10000 PPM |
| Accuracy: | CO2: ±40 PPM + 3% Of Reading |
Dwyer Digital Timer CT216-110 Dwyer LCT216-100 achometer / Counter
| Operating Temperature Ranges: | 32 To 122°F |
|---|---|
| Humidity Conditions: | 35 To 85% RH |
| Control Output Ratings: | Relay: SPST 5A At 250 VAC |